Year
1995
File Attachment
1301.PDF1.4 MB
Abstract
Heysham I and Hartlepool are sister Advanced Gas-Cooled Reactor (AGR) nuclear power plants operated by Nuclear Electric plc. They share a common design of gas circulator; a total of eight circulators being installed in each reactor to circulate the primary coolant, C02, through the reactor core and boilers. A total of four spare gas circulators were provided per station, which served to safeguard generation in the event of maintenance being required on an in-circuit unit. As an insurance measure against there being no fully overhauled gas circulator available, Nuclear Electric identified the requirements for a container module to transport a spare circulator between the stations should the need arise. In such circumstances, it would be necessary to transport a gas circulator safely and with the minimum of radiological impact while complying with the relevant transport standards and regulations. To this end, a Gas Circulator Transportation Module was designed, manufactured and tested, and a safety case prepared to demonstrate compliance with the IAEA Regulations for the Safe Transport or Radioactive Material, 1985 Edition (As Amended 1990).