Abstract
In the past, passive Nuclear Materials Identification System (NMIS) measurements on plutonium metal shells at VNIIEF have shown the sensitivity of the acquired covariance functions to shell mass and thickness for a variety of shell thicknesses from 6 to 30 mm and masses varying from 1829 to 4468g. The technique acquires the time-dependent coincidence distribution between plastic scintillators detecting radiation from the Pu. The measurements showed the sensitivity of the acquired signature to the different spontaneous emission, attenuation, and multiplication properties of the shells. In this work, the MCNP-POLIMI neutron and photon transport code was used to simulate passive measurements on plutonium metal and oxide. The code is a modified version of MCNP, which attempts to calculate more correctly quantities that depend on the second moment of the neutron and gamma distributions, and attempts to model detector pulses as closely as possible. MCNP-POLIMI, together with a post-processing code, can simulate all the time-dependent coincidence distributions measured by NMIS. In particular, the simulations evaluate the timedependent coincidence distributions between detectors for plutonium samples having mass 2 and 4 kg, in metal and oxide form. This work shows that the time-dependent coincidence distributions between two scintillators measured by NMIS can be used to distinguish metal from oxide.