The FORK measurement system, designed at Los Alamos National Laboratory (LANL) for the International Atomic Energy Agency (IAEA) safeguards program, has been used to examine spent reactor fuel assemblies at Duke Power Company's Oconee Nuclear Station. The FORK system measures the passive neutron and gamma-ray emission from spent fuel assemblies while in the storage pool. These measurements can be correlated with burnup and cooling time, and can be used to verify the reactor site records. Verification measurements may be used to help ensure nuclear criticality safety when burnup credit is applied to spent fuel transport and storage systems. By taking into account the reduced reactivity of spent fuel due to its burnup in the reactor, burnup credit results in more efficient and economic transport and storage. The objectives of these tests are to demonstrate the applicability of the FORK system to verify reactor records and to develop optimal procedures compatible with utility operations. The test program is a cooperative effort supported by Sandia National Laboratories, the Electric Power Research Institute (EPRI), Los Alamos National Laboratory, and the Duke Power Company.